Models: RG-N18010-XH Eight Service Slots, 100GE/400GE Line Cards
Highlight Features
- 100GE and 400GE line cards, and up to 288 x 400GE and 1152 x 100GE line-rate ports
- Communication at the maximum distance of 120 km and easy DCI
- Hardware-level redundancy, ensuring nonstop services and data center network stability
- MACsec data encryption and transmission, effectively protecting service data security
- Innovative technology design and efficient heat dissipation, with more than 50,000 kWh saved per device each year
- Telemetry-based network monitoring and automated O&M, making management simple and efficient

🎯 Data Center 400GE Modular Core Switch RG-N18010-XH
The RG-N18010-XH provides 10 module slots, including eight service slots, which can be used with 100GE and 400GE line cards. It supports 800GE line cards in the future, easily coping with future bandwidth expansion needs. With various port types, the RG-N18010-XH supports up to 288 x 400GE and 1152 x 100GE line-rate ports, and allows smooth evolution to 800GE, satisfying requirements in diversified scenarios of data center networks.

🎯 Innovative Architecture Design, Achieving Highly Efficient Data Transmission
Zero Midplane
Service line cards are directly connected to SFUs, without the use of the midplane. Data can directly reach the SFU, with a short distance. This significantly reduces the transmission loss and achieves efficient data transmission.

🎯 Innovative Architecture Design, Achieving Highly Efficient Data Transmission
Clos Architecture
The Clos multi-level multi-platform switching architecture separates data forwarding from control, realizing high stability. This architecture delivers
1:1 non-convergence, link load balancing based on dynamic routes, and non-blocking data forwarding.

🎯 Communication at the Maximum Distance of 120 KM and Easy DCI
400GE ZR/ZR+ optical modules are used for interconnection, reducing Optical Transport Units (OTUs) and helping a cloud or hyper-scale
data center network to adapt to growing high-bandwidth services
🎯 Hardware-level Redundancy, Ensuring Nonstop Services and Data Center Network Stability

🎯 Innovative Technology Design and Highly Efficient Heat Dissipation

🎯 MACsec Data Encryption and Transmission, Effectively Protecting Service Data Security
MACsec provides hardware-level data encryption. With MACsec and 802.1X configured, the switch can strictly identify and verify transmitted data. With MACsec, the switch achieves interface-based secure line-rate transmission, effectively preventing data from being intercepted and obtained maliciously
and ensuring service data security.

🎯 Telemetry-based Network Monitoring and Automated O&M, Making Management Simple and Efficient
The switch enabled with telemetry provides clear data status and hierarchy. The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.
| System Specifications | RG-N18010-XH |
| Switching Capacity | 645 Tbps/1,935 Tbps |
| Packet Forwarding Rate | 345,600 Mpps |
| Slots | |
| Module Slots | 10 (2 for supervisor modules) |
| Switch Fabric Module Slots | 8 |
| Fan module | Three fan module slots |
| Power module | Ten power module slots |
| Dimensions and Weight | |
| Dimensions (W x D x H) | Without cable management brackets: 442 mm x 896 mm x 708 mm (17.40 in. x 35.28 in. x 27.87 in., 16 RU) With cable management brackets: 442 mm x 935 mm x 708 mm (17.40 in. x 36.81 in. x 27.87 in., 16 RU) |
| Weight | 96.4 kg (212.53 lbs., including the fan) |
| Power Supply and Consumption | |
| Power Supply | RG-PAH3000I-F: ● AC: 100 V AC to 176 V AC, power: 1,500 W ● AC: 176 V AC to 240 V AC, power: 3,000 W ● HVDC: 240 V DC to 380 V DC, power consumption: 3,000 W |
| Airflow direction | Front-to-rear |
| Maximum Power Consumption | 18,760 W |
| Environment and Reliability | |
| MTBF | 312,683 hours |
| Operating Temperature | 0ºC to 40ºC (32ºF to 104ºF) |
| Storage Temperature | –40ºC to +70ºC (–40ºF to +158ºF) |
| Operating Humidity | 10% RH to 90% RH (non-condensing) |
| Storage humidity | 5% to 95% RH (non-condensing) |
| Altitude | ● Operating altitude for long-term working conditions: up to 5000 m (16404.20 ft.). At 1800 m (5905.51 ft.), the maximum operating temperature is 40°C (104°F). The maximum operating temperature decreases by 1°C (1.8°F) per 200 m (656.16 ft.) increase in altitude. ● Operating altitude: up to 5,000 m (16404.20 ft.) ● Storage altitude: up to 5,000 m (16404.20 ft.) |
| Software Specifications | RG-N18010-XH |
| Traffic Analysis | sFlow IPFIX |
| Layer 2 Features | Jumbo frame IEEE 802.3ad (static link aggregation, LACP, cross-card link aggregation, cross-device link aggregation) IEEE 802.1Q STP, RSTP, MSTP GVRP QinQ LLDP Static MAC addresses, address filtering, and limit on the number of MAC addresses |
| IPv4 Features | Static routing, RIP, OSPF, IS-IS, and BGP4 VRRP ECMP Policy-based routing Manual tunnel and GRE tunnel |
| IPv6 Features | Static routing, OSPFv3, BGP4+, IS-ISv6, and MLDv1/v2 VRRPv3 ECMP Policy-based routing Path MTU Discovery Manual tunnel and GRE tunnel Pingv6, telnetv6, FTPv6, TFTPv6, DNSv6, ICMPv6 |
| Multicast | IGMP v1/v2/v3 IGMP snooping IGMP proxy PIM-DM, PIM-SM, PIM-SSM, and other multicast routing protocols MLDv1, MLDv2 Multicast static routing Fast leave |
| MPLS | MPLS L3VPN MPLS LDP #SR MPLS (Segment Routing) #SR-TE |
| ACL | Standard, extended, and expert-level ACLs Global ACLs Ingress and egress ACLs IPv6 ACLs |
| QoS | Mapping of IEEE 802.1p, DSCP, and ToS priorities Priority marking/remarking Multiple queue scheduling mechanisms, including SP(PQ), DRR, SP(PQ) + DRR, WFQ, SP(PQ) + WFR, Congestion avoidance mechanisms such as RED and WRED ACL Ingress and egress rate limiting, CAR #MPLS QoS |
| Data center features | #SRv6 VXLAN bridge VXLAN gateway BGP-EVPN VXLAN VXLAN mapping IPv6 VXLAN over IPv4 MLAG |
| SDN | OpenFlow 1.3. |
| Reliability | Independent switch fabric modules and independent supervisor modules to implement thorough separation of the forwarding plane from the control plane 1+1 redundancy for supervisor modules N+1 redundancy for switch fabric modules N+M redundancy for power modules and fans Backplane-free design to avoid single point of failures Hot swapping of components Hot patch function and online installation of patches BPDU Guard/Loop Guard/Root Guard NSR DLDP FRR GR for OSPF/IS-IS/BGP BFD for VRRP/OSPF/BGP4/ISIS/ISISv6/static routing |
| Device virtualization | Virtual Switching Unit 3.0 |
| Security | MACSec Network Foundation Protection Policy (NFPP) and CPU protection policy (CPP) to prevent protocol packet attacks Prevention against DDoS, ARP, and ICMP attacks DAI, port security, IP source guard, and port protection uRPF RADIUS and TACACS user login authentication, password security, hierarchical user management, and password protection Source IP address restriction Function of not sending unknown multicast packets to the CPU Suppression of unknown multicast, unknown broadcast, and unknown multicast packets SSHv2, providing encrypted security channels for user login Plaintext and MD5 ciphertext authentication for OSPF, RIPv2, and BGP4 packets |
| Management | Console/AUX Modem/Telnet/SSH2.0 CLI configuration FTP, TFTP, Xmodem, and SFTP SNMP V1/V2c/V3 NETCONF RMON NTP clock Fault alarm and auto-recovery System operation logging Traffic analysis Zero-touch provisioning (ZTP) Reliable network service (RNS), which probes specific services provided by the peer device to monitor the service availability Telemetry Buffer status monitoring and traffic microburst identification Port mirroring, traffic mirroring, and ERSPAN Physical ports on all line cards support the routing mode and IP addresses can be configured independently. Monitoring of fan modules and power modules |
| Specifications | RG-N18010-XH |
| Safety | ● IEC 62368-1 ● EN IEC 62368-1 ● GB 4943.1 |
| Electromagnetic Compatibility (EMC) | ● EN 55032 ● EN 55035 ● EN IEC 61000-3-2 ● EN 61000-3-3 ● EN 300 386 V2.2.1 ● GB/T 9254.1 |
| Environment | ● 2011/65/EU EN 50581 ● 2012/19/EU EN 50419 ● (EC) No.1907/2006 ● GB/T 26572 |
Chassis and Supervisor Modules
| Model | Description |
| RG-N18010-XH | RG-N18010-XH chassis, excluding power modules, with all fans |
| M18000XH-CM | M18000XH-CM supervisor module |
Power Modules
| Model | Description |
| RG-PAH3000I-F | 3000 W AC power module (AC and 240 V to 380 V HVDC) |
Switch Fabric Modules
| Model | Description |
| M18018XH-FE-E IV | Type-E switch fabric module II for RG-N18010-XH, used together with CE cards |
| M18010XH-FE-E II | Type-E switch fabric module II for RG-N18010-XH, used together with CE cards |
Line Cards
| Model | Description |
| M18000XH-36QC-CES | Line card with 36 x 400GE QSFP-DD ports, used together with Type-E switch fabric modules |
| M18000XH-48CQ-CES | Line card with 48 x 100GE QSFP28 ports, used together with Type-E switch fabric modules |
400GBASE Series Optical Transceivers
| Model | Description |
| 400G-QDD-DR4-SM1310 | 400G DR4 transceiver, QSFP-DD form factor, MPO-12 APC, 1310 nm, 500 m (1,640.42 ft.) over SMF |
| 400G-QDD-FR4-SM1310 | 400G FR4 transceiver, QSFP-DD form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF |
| 400G-QDD-ZR-SM1550 | 400G ZR transceiver, QSFP-DD form factor, Duplex LC, 1550 nm, 80 km (262,467.19 ft.) over SMF |
| 400G-QDD-ZR+-SM1550 | 400G ZR+ transceiver, QSFP-DD form factor, Duplex LC, tunable wavelength, P2P distance of up to 120 km (393,700.79 ft.) over SMF |
| 400G-QDD-SR8-MM850 | 400G SR8 module, QSFP-DD form factor, MPO-16 APC, 850 nm, 100 m (328.08 ft.) over MMF |
100GBASE Series Optical Transceivers
| Model | Description |
| 100G-QSFP-LR4-SM1310 | 100G LR4 transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF |
| 100G-QSFP-iLR4-SM1310 | 100G iLR4 transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF |
| 100G-QSFP-ER4-SM1310 | 100G ER4 transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.59 ft.) over SMF |
| 100G-QSFP-SR-MM850 | 100G SR transceiver, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over MMF |
| 100G-AOC-5M | 100G AOC cable, QSFP28 form factor, 5 m (16.40 ft.) |
| 100G-AOC-10M | 100G AOC cable, QSFP28 form factor, 10 m (32.81 ft.) |
40GBASE Series Optical Transceivers
| Model | Description |
| 40G-QSFP-LX4-SM1310 | 40G LX4 transceiver, QSFP+ form factor, Duplex LC connector, 150 m (492.13 ft.) over OM3/OM4 MMF, or 2 km (6,561.68 ft.) over SMF |
| 40G-QSFP-LR4-SM1310 | 40G LR4 transceiver, QSFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF |
| 40G-QSFP-iLR4-SM1310 | 40G iLR4 transceiver, QSFP+ form factor, Duplex LC, 2 km (6,561.68 ft.) over SMF |
| 40G-QSFP-LSR-MM850 | 40G LSR transceiver, QSFP+ form factor, MPO, 400 m (1,312.34 ft.) over MMF |
| 40G-QSFP-SR-MM850 | 40G SR transceiver, QSFP+ form factor, MPO, 150 m (492.13 ft.) over MMF |
| 40G-AOC-30M | 40G AOC cable, QSFP+ form factor, 30 m (98.43 ft.) |
| 40G-AOC-5M | 40G AOC cable, QSFP+ form factor, 5 m (16.40 ft.) |
25GBASE Series Optical Transceivers
| Model | Description |
| VG-SFP-AOC5M | 25G AOC cable, SFP28 form factor, 5 m (16.40 ft.) |
| VG-SFP-SR-SM850 | 25G SR transceiver, SFP28 form factor, LC, 850 nm, 100 m (328.08 ft.) over MMF |
| VG-SFP-LR-SM1310 | 25G LR4 transceiver, QSFP28 form factor, LC, 1310 nm, 10 km (32,808.40 ft.) over SMF |


















Reviews