Skip to content
FEYANAFEYANA
    • Send an email
    • 08:00 - 17:00
    • +84 988 641 591
  • English
    • Tiếng Việt
    • English
    • 中文 (中国)
  • English
    • Tiếng Việt
    • English
    • 中文 (中国)
  • 0
    Cart

    No products in the cart.

    Return to shop

  • Products
      • Gearboxes
      • Electronics
      • Couplings
      • Assembly Technology
      • Bearings
      • Clutches & Brakes
      • Motors
      • Stationary Air Filtration Systems
      • Tools
      • Adhesives
      • Lubricants & Greases
      • Coating
      • Drives
      • HVAC Components
      • Valves
      • Wind Energy Technology
      • Communication & Connectivity
      • Grinding & Polishing Tools
        • Drive belt
  • Industries
      • Food & Beverage
      • Chemical
      • Energy & Ultilities
      • Pharmaceutics
      • Renewable Energy
      • Consumer Markets
      • Automotive
      • Electronics
      • Marine
      • Design & Contructions
      • Thermal Equipment
          • Textile Duct
          • Danfoss Drive for AHU System
          • Heat Exchangers
          • Novenco Axial Fan for AHU System
  • Brands
      • Bosch Rexroth
      • Rockwell Automation
        • Allen-Bradley
      • Danfoss
      • Regal Rexnord
      • Flender
      • SKF
      • RKB
      • Liebherr
      • FEYANA
      • BEKAWind
      • Wright
      • Motul
      • Molykote®
      • H.B Fuller
      • Schaeffler
      • Novenco
      • Trane
      • Teknos
      • Ecotherm
      • Engie
      • Continental Industrie
      • Netzsch
      • Enerpac
      • Chevron
      • CPC Lube
      • Schneider Electric
        • APC
      • H3C
      • Ruijie Networks
        • Reyee
      • EtherWAN
      • Innomotics
      • Ormazabal
      • Siemens
      • Daikin
      • LG
      • Hine
      • Skov
      • Jtekt
      • GAMESA ELECTRIC
      • IRUNA BRAKES
      • SVENDBORG BRAKES
      • Ebm Papst
      • Kema
      • Rocol
      • Osborn
      • FEYANA
      • Bosch
      • Hyosung Heavy Industries
      • Mitsuboshi
  • Blog Posts
  • Feature Projects
  • Products for lease
    • Rechargeable Electric Torque Wrench
  • IT Solution
    • Data Center
  • Login
  • Cart / 0 ₫ 0
    • No products in the cart.

      Return to shop

    • Send an email
    • 08:00 - 17:00
    • +84 988 641 591
RG-N18010-XH – Next Generation Data Center Network
RG-N18010-XH – Next Generation Data Center Network - Image 2
RG-N18010-XH – Next Generation Data Center Network - Image 3
RG-N18010-XH – Next Generation Data Center Network - Image 4
RG-N18010-XH – Next Generation Data Center Network - Image 5
RG-N18010-XH – Next Generation Data Center Network - Image 6
RG-N18010-XH – Next Generation Data Center Network
RG-N18010-XH – Next Generation Data Center Network - Image 2
RG-N18010-XH – Next Generation Data Center Network - Image 3
RG-N18010-XH – Next Generation Data Center Network - Image 4
RG-N18010-XH – Next Generation Data Center Network - Image 5
RG-N18010-XH – Next Generation Data Center Network - Image 6
Home / Communication & Connectivity / Switches / Data Center Switches

RG-N18010-XH – Next Generation Data Center Network

Density Centralized Modular Core Switch with 100GE/400GE Line Cards and Eight Service Slots

Adaptation to 400GE ZR/ZR+ optical modules, up to 288 x 400GE and 1152 x 100GE line-rate ports, and smooth evolution to 800GE

Categories: Communication & Connectivity, Data Center Switches, Switches Tags: Data Center Switches, Ethernet Switches Ruijie, Ruijie, Switches
Porfolio
  • Adhesives (10)
  • Assembly Technology (75)
  • Audi (0)
  • Automation (226)
  • Bearings (51)
  • Clutches & Brakes (46)
  • Coating (1)
  • Communication & Connectivity (56)
    • Accessories (3)
    • Routers (13)
    • Switches (22)
      • Campus Network Switches (2)
      • Data Center Switches (2)
      • Industrial Ethernet Switches (10)
      • iOptic Network (1)
      • SMB Switches (2)
      • SOHO Switches (2)
    • UPS ( Uninterruptible Power Supply ) (7)
    • Wireless (14)
  • Coupling (27)
  • Drive belt (15)
  • Drives (28)
  • Driveshafts (2)
  • Electrical Cabinet (7)
  • Gearboxes (36)
  • Grinding & Dispersing (10)
  • Grinding & Polishing Tools (61)
  • HVAC Components (119)
  • Industrial Blowers (3)
  • Livestock Equipment (67)
  • Lubricants & Greases (95)
  • Medium Voltage Portfolio (3)
  • Motors (41)
  • Oxygen & Nitrogen Gas Generator (12)
  • Polypropylene (18)
  • Stationary Air Filtration Systems (7)
  • Tools (125)
  • Valves (15)
  • Wind Energy Technology (47)
  • Description
  • Reviews (0)

Models: RG-N18010-XH Eight Service Slots, 100GE/400GE Line Cards

Series: RG-N18000-XH Series

Highlight Features

  • 100GE and 400GE line cards, and up to 288 x 400GE and 1152 x 100GE line-rate ports
  • Communication at the maximum distance of 120 km and easy DCI
  • Hardware-level redundancy, ensuring nonstop services and data center network stability
  • MACsec data encryption and transmission, effectively protecting service data security
  • Innovative technology design and efficient heat dissipation, with more than 50,000 kWh saved per device each year
  • Telemetry-based network monitoring and automated O&M, making management simple and efficient
  • Key Specification
  • Features
  • Specifications
  • Ordering Information
Switching Capacity: 645 Tbps/1,935 Tbps
Packet Forwarding Rate: 45,600 Mpps
Switch Fabric Module Slots: 8
Module Slots: 10 (2 for supervisor modules)
Dimensions (W × D × H): 442 mm x 896 mm x 708 mm (17.40 in. x 35.28 in. x 27.87 in., 16 RU)
Operating Temperature: 0ºC to 40ºC (32ºF to 104ºF)
Operating Humidity: 10% RH to 90% RH (non-condensing)

🎯 Data Center 400GE Modular Core Switch RG-N18010-XH

The RG-N18010-XH provides 10 module slots, including eight service slots, which can be used with 100GE and 400GE line cards. It supports 800GE line cards in the future, easily coping with future bandwidth expansion needs. With various port types, the RG-N18010-XH supports up to 288 x 400GE and 1152 x 100GE line-rate ports, and allows smooth evolution to 800GE, satisfying requirements in diversified scenarios of data center networks.

🎯 Innovative Architecture Design, Achieving Highly Efficient Data Transmission

Zero Midplane

Service line cards are directly connected to SFUs, without the use of the midplane. Data can directly reach the SFU, with a short distance. This significantly reduces the transmission loss and achieves efficient data transmission.

🎯 Innovative Architecture Design, Achieving Highly Efficient Data Transmission

Clos Architecture

The Clos multi-level multi-platform switching architecture separates data forwarding from control, realizing high stability. This architecture delivers
1:1 non-convergence, link load balancing based on dynamic routes, and non-blocking data forwarding.

🎯 Communication at the Maximum Distance of 120 KM and Easy DCI

400GE ZR/ZR+ optical modules are used for interconnection, reducing Optical Transport Units (OTUs) and helping a cloud or hyper-scale
data center network to adapt to growing high-bandwidth services

🎯 Hardware-level Redundancy, Ensuring Nonstop Services and Data Center Network Stability

SFUs in N+1 Redundancy Mode SFUs use N+1 redundancy and work in load balancing mode, ensuring nonstop services.
Power Modules in M+N Redundancy Mode Ten hot-swappable power modules are available. When a fault occurs, services are switched within seconds. Services are not interrupted when a power module is replaced. The switch provides different protection measures for links.
Fan Trays in 2+1 Redundancy Mode Three hot-swappable fan trays are available. The speed of fan modules can be intelligently adjusted, ensuring highly efficient heat dissipation.
Supervisor Engin es in 1+1 Redundancy Mode The 1+1 hot standby design ensure continuous operation of the switch.

🎯 Innovative Technology Design and Highly Efficient Heat Dissipation

🎯 MACsec Data Encryption and Transmission, Effectively Protecting Service Data Security

MACsec provides hardware-level data encryption. With MACsec and 802.1X configured, the switch can strictly identify and verify transmitted data. With MACsec, the switch achieves interface-based secure line-rate transmission, effectively preventing data from being intercepted and obtained maliciously
and ensuring service data security.

🎯 Telemetry-based Network Monitoring and Automated O&M, Making Management Simple and Efficient

The switch enabled with telemetry provides clear data status and hierarchy. The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.

Hardware Specifications
System SpecificationsRG-N18010-XH
Switching Capacity645 Tbps/1,935 Tbps
Packet Forwarding Rate345,600 Mpps
Slots
Module Slots10 (2 for supervisor modules)
Switch Fabric Module Slots8
Fan moduleThree fan module slots
Power moduleTen power module slots
Dimensions and Weight
Dimensions (W x D x H)Without cable management brackets: 442 mm x 896 mm x 708 mm (17.40 in. x 35.28 in. x 27.87 in., 16 RU)

With cable management brackets: 442 mm x 935 mm x 708 mm (17.40 in. x 36.81 in. x 27.87 in., 16 RU)

Weight96.4 kg (212.53 lbs., including the fan)
Power Supply and Consumption
Power SupplyRG-PAH3000I-F:

● AC: 100 V AC to 176 V AC, power: 1,500 W

● AC: 176 V AC to 240 V AC, power: 3,000 W

● HVDC: 240 V DC to 380 V DC, power consumption: 3,000 W

Airflow directionFront-to-rear
Maximum Power Consumption18,760 W
Environment and Reliability
MTBF312,683 hours
Operating Temperature0ºC to 40ºC (32ºF to 104ºF)
Storage Temperature–40ºC to +70ºC (–40ºF to +158ºF)
Operating Humidity10% RH to 90% RH (non-condensing)
Storage humidity5% to 95% RH (non-condensing)
Altitude● Operating altitude for long-term working conditions: up to 5000 m (16404.20 ft.). At 1800 m (5905.51 ft.), the maximum operating temperature is 40°C (104°F). The maximum operating temperature decreases by 1°C (1.8°F) per 200 m (656.16 ft.) increase in altitude.

● Operating altitude: up to 5,000 m (16404.20 ft.)

● Storage altitude: up to 5,000 m (16404.20 ft.)

Software Specifications
Software SpecificationsRG-N18010-XH
Traffic AnalysissFlow

IPFIX

Layer 2 FeaturesJumbo frame

IEEE 802.3ad (static link aggregation, LACP, cross-card link aggregation, cross-device link aggregation)

IEEE 802.1Q

STP, RSTP, MSTP

GVRP

QinQ

LLDP

Static MAC addresses, address filtering, and limit on the number of MAC addresses

IPv4 FeaturesStatic routing, RIP, OSPF, IS-IS, and BGP4

VRRP

ECMP

Policy-based routing

Manual tunnel and GRE tunnel

IPv6 FeaturesStatic routing, OSPFv3, BGP4+, IS-ISv6, and MLDv1/v2

VRRPv3

ECMP

Policy-based routing

Path MTU Discovery

Manual tunnel and GRE tunnel

Pingv6, telnetv6, FTPv6, TFTPv6, DNSv6, ICMPv6

MulticastIGMP v1/v2/v3

IGMP snooping

IGMP proxy

PIM-DM, PIM-SM, PIM-SSM, and other multicast routing protocols

MLDv1, MLDv2

Multicast static routing

Fast leave

MPLSMPLS L3VPN

MPLS LDP

#SR MPLS (Segment Routing)

#SR-TE

ACLStandard, extended, and expert-level ACLs

Global ACLs

Ingress and egress ACLs

IPv6 ACLs

QoSMapping of IEEE 802.1p, DSCP, and ToS priorities
Priority marking/remarking
Multiple queue scheduling mechanisms, including SP(PQ), DRR, SP(PQ) + DRR, WFQ, SP(PQ) + WFR,
Congestion avoidance mechanisms such as RED and WRED

ACL

Ingress and egress rate limiting, CAR

#MPLS QoS

Data center features#SRv6

VXLAN bridge

VXLAN gateway

BGP-EVPN VXLAN

VXLAN mapping

IPv6 VXLAN over IPv4

MLAG

SDNOpenFlow 1.3.
ReliabilityIndependent switch fabric modules and independent supervisor modules to implement thorough separation of the forwarding plane from the control plane

1+1 redundancy for supervisor modules

N+1 redundancy for switch fabric modules

N+M redundancy for power modules and fans

Backplane-free design to avoid single point of failures

Hot swapping of components

Hot patch function and online installation of patches

BPDU Guard/Loop Guard/Root Guard

NSR

DLDP

FRR

GR for OSPF/IS-IS/BGP

BFD for VRRP/OSPF/BGP4/ISIS/ISISv6/static routing

Device virtualizationVirtual Switching Unit 3.0
SecurityMACSec

Network Foundation Protection Policy (NFPP) and CPU protection policy (CPP) to prevent protocol packet attacks

Prevention against DDoS, ARP, and ICMP attacks

DAI, port security, IP source guard, and port protection

uRPF

RADIUS and TACACS user login authentication, password security, hierarchical user management, and password protection

Source IP address restriction

Function of not sending unknown multicast packets to the CPU

Suppression of unknown multicast, unknown broadcast, and unknown multicast packets

SSHv2, providing encrypted security channels for user login
Prevention against MAC address flapping

Plaintext and MD5 ciphertext authentication for OSPF, RIPv2, and BGP4 packets

ManagementConsole/AUX Modem/Telnet/SSH2.0 CLI configuration

FTP, TFTP, Xmodem, and SFTP SNMP V1/V2c/V3

NETCONF

RMON

NTP clock

Fault alarm and auto-recovery

System operation logging

Traffic analysis

Zero-touch provisioning (ZTP)

Reliable network service (RNS), which probes specific services provided by the peer device to monitor the service availability

Telemetry

Buffer status monitoring and traffic microburst identification

Port mirroring, traffic mirroring, and ERSPAN

Physical ports on all line cards support the routing mode and IP addresses can be configured independently.

Monitoring of fan modules and power modules

Safety and Regulatory Compliance
SpecificationsRG-N18010-XH
Safety● IEC 62368-1

● EN IEC 62368-1

● GB 4943.1

Electromagnetic Compatibility (EMC)● EN 55032

● EN 55035

● EN IEC 61000-3-2

● EN 61000-3-3

● EN 300 386 V2.2.1

● GB/T 9254.1

Environment● 2011/65/EU EN 50581

● 2012/19/EU EN 50419

● (EC) No.1907/2006

● GB/T 26572

Chassis and Supervisor Modules

ModelDescription
RG-N18010-XHRG-N18010-XH chassis, excluding power modules, with all fans
M18000XH-CMM18000XH-CM supervisor module

Power Modules

ModelDescription
RG-PAH3000I-F3000 W AC power module (AC and 240 V to 380 V HVDC)

Switch Fabric Modules

ModelDescription
M18018XH-FE-E IVType-E switch fabric module II for RG-N18010-XH, used together with CE cards
M18010XH-FE-E IIType-E switch fabric module II for RG-N18010-XH, used together with CE cards

Line Cards

ModelDescription
M18000XH-36QC-CESLine card with 36 x 400GE QSFP-DD ports, used together with Type-E switch fabric modules
M18000XH-48CQ-CESLine card with 48 x 100GE QSFP28 ports, used together with Type-E switch fabric modules

400GBASE Series Optical Transceivers

ModelDescription
400G-QDD-DR4-SM1310400G DR4 transceiver, QSFP-DD form factor, MPO-12 APC, 1310 nm, 500 m (1,640.42 ft.) over SMF
400G-QDD-FR4-SM1310400G FR4 transceiver, QSFP-DD form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF
400G-QDD-ZR-SM1550400G ZR transceiver, QSFP-DD form factor, Duplex LC, 1550 nm, 80 km (262,467.19 ft.) over SMF
400G-QDD-ZR+-SM1550400G ZR+ transceiver, QSFP-DD form factor, Duplex LC, tunable wavelength, P2P distance of up to 120 km (393,700.79 ft.) over SMF
400G-QDD-SR8-MM850400G SR8 module, QSFP-DD form factor, MPO-16 APC, 850 nm, 100 m (328.08 ft.) over MMF

100GBASE Series Optical Transceivers

ModelDescription
100G-QSFP-LR4-SM1310100G LR4 transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF
100G-QSFP-iLR4-SM1310100G iLR4 transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF
100G-QSFP-ER4-SM1310100G ER4 transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.59 ft.) over SMF
100G-QSFP-SR-MM850100G SR transceiver, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over MMF
100G-AOC-5M100G AOC cable, QSFP28 form factor, 5 m (16.40 ft.)
100G-AOC-10M100G AOC cable, QSFP28 form factor, 10 m (32.81 ft.)

40GBASE Series Optical Transceivers

ModelDescription
40G-QSFP-LX4-SM131040G LX4 transceiver, QSFP+ form factor, Duplex LC connector, 150 m (492.13 ft.) over OM3/OM4 MMF, or 2 km (6,561.68 ft.) over SMF
40G-QSFP-LR4-SM131040G LR4 transceiver, QSFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF
40G-QSFP-iLR4-SM131040G iLR4 transceiver, QSFP+ form factor, Duplex LC, 2 km (6,561.68 ft.) over SMF
40G-QSFP-LSR-MM85040G LSR transceiver, QSFP+ form factor, MPO, 400 m (1,312.34 ft.) over MMF
40G-QSFP-SR-MM85040G SR transceiver, QSFP+ form factor, MPO, 150 m (492.13 ft.) over MMF
40G-AOC-30M40G AOC cable, QSFP+ form factor, 30 m (98.43 ft.)
40G-AOC-5M40G AOC cable, QSFP+ form factor, 5 m (16.40 ft.)

25GBASE Series Optical Transceivers

ModelDescription
VG-SFP-AOC5M25G AOC cable, SFP28 form factor, 5 m (16.40 ft.)
VG-SFP-SR-SM85025G SR transceiver, SFP28 form factor, LC, 850 nm, 100 m (328.08 ft.) over MMF
VG-SFP-LR-SM131025G LR4 transceiver, QSFP28 form factor, LC, 1310 nm, 10 km (32,808.40 ft.) over SMF

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Related products

RG-AP9861-R, Wi-Fi 7 24.436 Gbps Indoor Access Point, 18 Spatial Streams, Built-in AI Radio

RG-AP9861-R, Wi-Fi 7 24.436 Gbps Indoor Access Point, 18 Spatial Streams, Built-in AI Radio

H3C WX5860X New Generation High Performance Multi-Service Access Controller

H3C WX5860X New Generation High Performance Multi-Service Access Controller

RG-SG7008L, Fixed 10G Integrated Switch, Supporting PoE+

RG-SG7008L, Fixed 10G Integrated Switch, Supporting PoE+

OttoE PoE H Series - Ethernet Switches

OttoE PoE H Series – Ethernet Switches

OttoE Series - Ethernet Switches

OttoE Series – Ethernet Switches

RG-RSR77-XA-03 5 RU Multiservice Core Modular Router

RG-RSR77-XA-03 5 RU Multiservice Core Modular Router

H3C WA7539 Wi-Fi 7(802.11be) Indoor Series Access Points

H3C WA7539 Wi-Fi 7(802.11be) Indoor Series Access Points

EX78900G Series - Ethernet Switches

EX78900G Series – Ethernet Switches

ABOUT US

About Feyana
Carrer
Shareholder relationship
Partners and Suppliers
Sustainability/ ESG

NEWS

News

Regulations

Safety Information Table & Compliance Standards
Search for transportation information

HELP CENTER

Help Center
Web maps
Find an office

Contact & follow us

Visa
PayPal
Stripe
MasterCard
Cash On Delivery
Copyright 2026 © Designed by DTA - Feyana Company Limited
  • Products
      • Gearboxes
      • Electronics
      • Couplings
      • Assembly Technology
      • Bearings
      • Clutches & Brakes
      • Motors
      • Stationary Air Filtration Systems
      • Tools
      • Adhesives
      • Lubricants & Greases
      • Coating
      • Drives
      • HVAC Components
      • Valves
      • Wind Energy Technology
      • Communication & Connectivity
      • Grinding & Polishing Tools
        • Drive belt
  • Industries
      • Food & Beverage
      • Chemical
      • Energy & Ultilities
      • Pharmaceutics
      • Renewable Energy
      • Consumer Markets
      • Automotive
      • Electronics
      • Marine
      • Design & Contructions
      • Thermal Equipment
          • Textile Duct
          • Danfoss Drive for AHU System
          • Heat Exchangers
          • Novenco Axial Fan for AHU System
  • Brands
      • Bosch Rexroth
      • Rockwell Automation
        • Allen-Bradley
      • Danfoss
      • Regal Rexnord
      • Flender
      • SKF
      • RKB
      • Liebherr
      • FEYANA
      • BEKAWind
      • Wright
      • Motul
      • Molykote®
      • H.B Fuller
      • Schaeffler
      • Novenco
      • Trane
      • Teknos
      • Ecotherm
      • Engie
      • Continental Industrie
      • Netzsch
      • Enerpac
      • Chevron
      • CPC Lube
      • Schneider Electric
        • APC
      • H3C
      • Ruijie Networks
        • Reyee
      • EtherWAN
      • Innomotics
      • Ormazabal
      • Siemens
      • Daikin
      • LG
      • Hine
      • Skov
      • Jtekt
      • GAMESA ELECTRIC
      • IRUNA BRAKES
      • SVENDBORG BRAKES
      • Ebm Papst
      • Kema
      • Rocol
      • Osborn
      • FEYANA
      • Bosch
      • Hyosung Heavy Industries
      • Mitsuboshi
  • Blog Posts
  • Feature Projects
  • Products for lease
    • Rechargeable Electric Torque Wrench
  • IT Solution
    • Data Center
  • Login
  • Newsletter

Login

Lost your password?